Models
S113C S114C S331C S332C S251C S810A S818A S820A
Frequency
Range (MHz) 2-1600 2-1600 25-4000 25-4000 625-2500 3.3-10.5 GHz 3.3-18 GHz 3.3-20 GHz
Resolution kHz 10 10 100 100 10 1 MHz 1 MHz 1 MHz
Markers 6666 6 4 4 4
Display
Point (Max.) 517 517 517 517 517 130 130 130
Interference
Immunity (dBm)
On-Frequency
(1)
+10 +10 –5 –5 +10 RF Out; +30 dBc RF In
(3)
–10 –10 –10
On-Channel
(2)
+17 +17 +17 +17 +17 N/A N/A N/A
Calibration:
Instrument
Configurations 10 10 10 10 10 6 6 6
Data Storage
Reporting:
Alpha Numeric Ye s Ye s Ye s Ye s Ye s N o N o N o
Time/Date Stamp Ye s Ye s Ye s Ye s Ye s N o N o N o
Numeric Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
Memory
Locations (Max.) 200 200 200 200 200 70 70 70
Measurement
Characteristics
(4)
Return Loss ✓✓✓✓ ✓ ✓ ✓ ✓
SWR ✓✓✓✓ ✓ ✓ ✓ ✓
Cable Loss ✓✓✓✓ ✓ ✓ ✓ ✓
DTF ✓✓✓✓ ✓ ✓ ✓ ✓
Insertion Gain ✓
Isolation ✓
Insertion Loss ✓
Spectrum Analysis N/A 0.1-1600 MHz N/A 0.1-3000 MHz N/A N/A N/A N/A
8
NEVER BEFORE HAS ONE ANALYZER FAMILY SOLVED SO
MANY ANTENNA SYSTEM PROBLEMS
Whether your system is cellular, PCS/DCS, 3G, paging, data, SMR, WLAN/WPBX or any other type of wireless service covering
the 2 MHz to 20 GHz frequency range, Site Master by Anritsu offers a cable and antenna analyzer solution for you.
1. On-Frequency Interference Immunity is specified to within ±10 kHz of the carrier frequency.
2. On-Channel Interference Immunity is specified at >1 MHz of the carrier frequency.
3. In most field applications, Immunity is typically better because interferring signals are modulated and varying in frequency rather than CW. Measurements were
made in CW mode by injecting a signal into the Site Master through a coupler.
4. All Anritsu Site Master models include Return Loss, SWR, Cable Loss, and Distance-To-Fault.