File Management 4-4 File Menu
Site Master User Guide PN: 10580-00252 Rev. A 4-9
Save On Event Menu
Key Sequence: File > Save On Event
Figure 4-9. Select Save Location Dialog Box
In Spectrum Analyzer mode, this menu is used to auto save measurements
to internal memory after:
...Crossing Limit: Toggling this submenu key to On will save the
measurement to internal memory when the measurement has crossed a
defined limit line created with the Limit menu.
...Sweep Complete: Toggling this submenu key to On will save the
measurement to internal memory after the current sweep is complete. If
Save Then Stop is toggled Off, a measurement will be saved after every
sweep.
Save Then Stop: Set this key to On to stop the sweep after a
measurement is saved. With this key Off and Sweep Complete On a
measurement is saved after every sweep.
Clear All: Pressing this key will turn Off the three save on event keys:
Crossing Limit
Sweep Complete
Save Then Stop
Figure 4-10. Save On Menu
Back
Clear All
Save On...
...Crossing Limit
On Off
...Sweep Complete
On Off
Save Then Stop
On Off