34. Press the STOP soft key.
35. For the S114C, enter
1600 then press the
MHz soft key to set the stop frequency to
1600 MHz.
For the S332C, enter
2000 then press the
MHz soft key to set the stop frequency to
2000 MHz.
36. Wait until a full sweep is complete.
37. Press the
MARKER key and then press
the
M1 soft key.
38. Press the
MARKER TO PEAK soft key. Re
-
cord the M1 amplitude reading and ver
-
ify it is £ –95 dBm.
NOTE
Continue to Step 39 only if the unit is a Site
Master Model S332C.
39. Press the
FREQ/DIST key and the START
soft key.
40. Enter
2000 and press the MHz soft key to
set the start frequency to 2000 MHz.
41. Press the
STOP soft key and enter 3000,
then press the MHz soft key to set the
stop frequency to 3000 MHz.
42. Wait until a full sweep is complete.
43. Press the
MARKER key and then press
the
M1 soft key.
44. Press the
MARKER TO PEAK soft key. Re-
cord the M1 amplitude reading and ver
-
ify it is £ –95 dBm.
12. SPECTRUM ANALYZER DYNAMIC
RANGE TEST
This test can be used to verify the dynamic range of
the Site Master spectrum analyzer.
a. Equipment required:
·
Two Anritsu MG3692A Synthesized Sig
-
nal Sources with options 2A, 4 and 15A,
or equivalent
·
Anritsu N241A50 Power Splitter or
equivalent
·
Anritsu 34NN50A 50 ohm adapter or
equivalent
·
Anritsu 34RSN50 50 ohm adapter or
equivalent
b. Procedure:
1. Connect the output of the Power Splitter
to the
RF In port of the Site Master Spec
-
trum Analyzer.
2. Connect the output of the both signal
sources to the input of the Power Split
-
ter.
3. Turn on both sources.
4. On the Site Master, press and hold the
ESCAPE/CLEAR key, then press the
ON/OFF key to turn on the Site Master.
(This sets the instrument to the factory
preset state.)
NOTE
Before continuing, allow a 30-minute warm up
for the internal circuitry to stabilize.
5. Set the CW frequency of the first source
to 1.0 GHz.
6. Set the CW frequency of the second
source to 1.2 GHz.
7. On the Site Master, press the
MODE key.
Use the up/down arrow key to highlight
SPECTRUM ANALZYER and press ENTER
to select spectrum analyzer mode.
8. Press the
FREQ/DIST key.
9. Press the
CENTER soft key, enter 1100,
then press the
MHz soft key to set the
center frequency to 1100 MHz.
10. Press the
SPAN soft key and enter 500,
then press the
MHz key to set the span to
500 MHz.
11. Press the
AMPLITUDE key and then the
REF LEVEL soft key.
12. Enter
–20 and then press the ENTER key
to set the reference level to –20 dBm.
13. Press the
SWEEP key.
14. Press the
RBW soft key and then the
MANUAL soft key. Use the Up/down arrow
key to select
30 kHz, the press ENTER to
set the resolution bandwidth to 30 kHz.
15. Press
BACK, then the VBW soft key and
then the
MANUAL soft key. Use the
Up/down arrow key to select
30 kHz, then
press
ENTER to set the video bandwidth
to 30 kHz.
Site Master S114C/S332C MM 11