10 Product Brochure
l
MG3700A
Options
Hardware Options
Model: MG3700A-001
Name: Rubidium Reference Oscillator
This option provides a 10 MHz reference signal VCO.
The frequency stability is better than the standard VCO.
Frequency: 10 MHz
Aging rate: ±1 × 10
–10
/month
Temperature stability: ±1 × 10
–9
(0° to +50°C)
Model: MG3700A-002
Name: Mechanical Attenuator
This option changes the standard electronic attenuator to a
mechanical attenuator, improving the maximum permissible
output level and distortion characteristics.
Settable range: –140 to +19 dBm
Accuracy range (CW): –140 to +10 dBm
Model: MG3700A-011
Name: Upper Frequency 6 GHz
This option extends the upper frequency to 6 GHz from 3 GHz.
Model: MG3700A-021
Name: ARB Memory Upgrade 512 Msamples
This option extends the memory capacity of the ARB unit to
256 Msamples/channel × 2 from 128 Msamples/channel × 2.
Model: MG3700A-031
Name: High-speed BER Test function
This option upgrades the standard built-in BER
measurement functions as follows:
• Increases the data rate to a range of 100 bps to 120 Mbps
• Added SyncLoss count function
• Added discontinuous PN data measurement function
• Added user pattern measurement function
Comparison between Standard BER Measurement
Function and Option BER Measurement Function
Standard BER
Measurement Function
(ver2.02 or later)
MG3700A-031/131
High-speed BER
Test Function
Case
On/Off function of
Auto Resync
√
√
+ Threshold
adjustment
Can perform continuous measurement of high
error rates by changing measurement conditions to
match error rates.
Auto Resync = OFF is required for manufacturing
inspection of some communications systems
requiring reception sensitivity with BER=1%, and
for R&D applications that evaluate reception
sensitivity limits.
Count
Mode
∗
Time
√
—
Measurement range can be set.
Data Bit/
Data
√ √
Error —
√
Measurement data
rate upper limit
20
Mbps
120
Mbps
This can be used for WLAN and next-generation
high-speed communications systems.
SyncLoss count
function
—
√
This can be used for continuous measurement
even when synchronization loss occurs.
Measurement of
discontinuous PN
data
—
√
When the size of continuous data such ISDB-T
PN23 exceeds the MG3700A memory capacity,
measurement can be performed by reducing the
memory requirements using discontinuous PN data.
User pattern
measurement
—
√
This can be used for measuring xed patterns such
as those specied by WiMAX.
∗:
The measurement count of the standard BER measurement function (version 2.02 or earlier)
could be set as Time and Number of bits. The High-speed BER Test Function option does
not have the Time setting, and can set Number of bits and Number of error bits.
Measurement System