10 Product Brochure
l
MG3700A
Options
Hardware Options
Model: MG3700A-001
Name: Rubidium Reference Oscillator
This option provides a 10 MHz reference signal VCO.
The frequency stability is better than the standard VCO.
Frequency: 10 MHz
Aging rate: ±1 × 10
–10
/month
Temperature stability: ±1 × 10
–9
(0° to +50°C)
Model: MG3700A-002
Name: Mechanical Attenuator
This option changes the standard electronic attenuator to a
mechanical attenuator, improving the maximum permissible
output level and distortion characteristics.
Settable range: –140 to +19 dBm
Accuracy range (CW): –140 to +10 dBm
Model: MG3700A-011
Name: Upper Frequency 6 GHz
This option extends the upper frequency to 6 GHz from 3 GHz.
Model: MG3700A-021
Name: ARB Memory Upgrade 512 Msamples
This option extends the memory capacity of the ARB unit to
256 Msamples/channel × 2 from 128 Msamples/channel × 2.
Model: MG3700A-031
Name: High-speed BER Test function
This option upgrades the standard built-in BER
measurement functions as follows:
Increases the data rate to a range of 100 bps to 120 Mbps
Added SyncLoss count function
Added discontinuous PN data measurement function
Added user pattern measurement function
Comparison between Standard BER Measurement
Function and Option BER Measurement Function
Standard BER
Measurement Function
(ver2.02 or later)
MG3700A-031/131
High-speed BER
Test Function
Case
On/Off function of
Auto Resync
+ Threshold
adjustment
Can perform continuous measurement of high
error rates by changing measurement conditions to
match error rates.
Auto Resync = OFF is required for manufacturing
inspection of some communications systems
requiring reception sensitivity with BER=1%, and
for R&D applications that evaluate reception
sensitivity limits.
Count
Mode
Time
Measurement range can be set.
Data Bit/
Data
Error
Measurement data
rate upper limit
20
Mbps
120
Mbps
This can be used for WLAN and next-generation
high-speed communications systems.
SyncLoss count
function
This can be used for continuous measurement
even when synchronization loss occurs.
Measurement of
discontinuous PN
data
When the size of continuous data such ISDB-T
PN23 exceeds the MG3700A memory capacity,
measurement can be performed by reducing the
memory requirements using discontinuous PN data.
User pattern
measurement
This can be used for measuring xed patterns such
as those specied by WiMAX.
:
The measurement count of the standard BER measurement function (version 2.02 or earlier)
could be set as Time and Number of bits. The High-speed BER Test Function option does
not have the Time setting, and can set Number of bits and Number of error bits.