16 Product Brochure
l
MG3700A
Convert: Data format conversion
ASCII-format IQ sample data created by general signal generation
software (such as MATLAB) can be converted to waveform
patterns for the MG3700A.
Data produced during R&D simulations can be converted using the
IQproducer and moved to the MG3700A to produce signals that
accurately reproduce the simulation data.
Convert Screen
AWGN Screen
File generation: File Gen
Additive White Gaussian Noise (AWGN) waveform generation
This function establishes the sampling rate and bandwidth, allowing
any AWGN waveform pattern to be created.
In addition, when the first combined waveform pattern (Wanted
Signal) is selected, the Wanted Signal bandwidth and sampling rate
are set automatically.
The resulting AWGN waveform pattern can be combined with an
existing waveform pattern, which is useful for base-station
dynamic-range measurements.
Main setting parameters
(1) Wanted Signal BW: Wanted Signal bandwidth
Setting range: 0.0010 to 120.0000 MHz
(2) AWGN BW (B)/Wanted Signal BW (A):
Magnification of AWGN to Wanted Signal
Setting range: 1.0, 1.5, 2.0, 2.5
(3) Sampling Rate:
Setting range: 0.0200 to 160.0000 MHz
Same value as Wanted Signal.
(4) AWGN BW (B): Bandwidth of AWGN
Calculated automatically from (1) and (2) under following items:
Limit range: 0.001 to 20.000 MHz and Sampling rate/2 max.
20.001 to 120.000 MHz and Sampling rate max.
Clipping
This function performs clipping of each type of waveform pattern.
The clipped waveform pattern is created by setting the filter,
bandwidth, and repletion times.
Clipping Graph