Vue de la page 90
Product Brochure
l
MX3701xxA 35
Visual Check on Frame Structure Screen
MX370108A LTE IQproducer
Displays Frame Structure screen for
confirming channel allocation status
and power of each OFDM Symbol
Display Resource Element allocation
graphically with each channel color-coded.
Y-axis: Frequency (Resource Block units)
X-axis: Time (OFDM Symbol units)
Display power relative levels of OFDM
Symbols with maximum power of 0 dB.
Y-axis: OFDM Symbol Power
X-axis: Time (OFDM Symbol units)
Frame Structure Screen
Optional
Common Parameter Setting Range
Display Outline Setting Range
Common
Duplex Displays duplex Display only: FDD
Number of Antennas Sets number of antennas 1, 2, 4 (2 and 4 only at Downlink)
Diversity Method Sets diversity method Spatial Multiplexing, Tx Diversity
Precoding Method Sets precoding method Without CDD, Large-delay CDD
Number of Layers Sets number of layers 1, 2, 3, 4
Number of Code words Sets number of Code word 1, 2
Codebook index Sets codebook index 0 to 15
Physical-layer Cell-identity Group
NID (1)
Sets physical-layer cell-identity group NID (1)
0 to 167
Physical-layer Identity NID (2) Sets physical-layer identity NID (2) 0, 1, 2
Cell ID Displays cell ID 0 to 503
PHICH Sets ON/OFF of PHICH ON, OFF
Ng
Sets parameter (Ng) that decides the
arrangement of PHICH
1/6, 1/2
Number of Frames Sets number of frames 1 to max. number of frames in memory
Over Sampling Ratio Sets over sampling ratio 2, 4
Sampling Rate Displays sampling rate Display only: Autosetting using oversampling ratio and bandwidth
Bandwidth Sets system bandwidth 1.4, 1.6, 3.0, 3.2, 5, 10, 15, 20 MHz
DL/UL Sets downlink/uplink settings Downlink, Uplink
Cyclic Prex Sets cyclic prex Normal, Extended
Subcarrier Spacing Displays subcarrier spacing Display only
Number of OFDM symbols per slot
Displays number of OFDM symbols per slot 7 (only when Cyclic Prex = Normal), 6 (only when Cyclic Prex = Extended)
Roll Off Length Sets roll-off length for OFDM symbol
0 to 3152 Ts (when Random Access Preamble)
0 to 144 Ts (when Cyclic Prex = Normal)
0 to 512 Ts (when Cyclic Prex = Extended)
Filter
Filter Type Sets lter type Nyquist, Root Nyquist, Ideal, None
Roll Off Sets roll-off rate 0.1 to 1.0 (only enabled for Nyquist, Root Nyquist)
Filter Length Set lter tap count in sample units 1 to 1024 (only enabled for Nyquist, Root Nyquist)